TY - JOUR
T1 - Vacuum-assisted closure for deep infection after spinal instrumentation for scoliosis
AU - Canavese, F.
AU - Gupta, S.
AU - Krajbich, J. I.
AU - Emara, K. M.
N1 - J Bone Joint Surg Br. 2008 Mar;90(3):377-81. doi: 10.1302/0301-620X.90B3.19890.
PY - 2008/3
Y1 - 2008/3
N2 - Our aim was to review the efficacy of the wound vacuum-assisted closure (VAC) system in the treatment of deep infection after extensive instrumentation and fusion for spinal deformity in children and adolescents. A total of 14 patients with early deep spinal infection were treated using this technique. Of these, 12 had neuromuscular or syndromic problems. Clinical and laboratory data were reviewed. The mean follow-up was 44 months (24 to 72). All wounds healed. Two patients required plastic surgery to speed up the process. In no patient was the hardware removed and there was no loss of correction or recurrent infection. We believe that the wound VAC system is a useful tool in the armamentarium of the spinal surgeon dealing with patients susceptible to wound infections, especially those with neuromuscular diseases. It allows for the retention of the instrumentation and the maintenance of spinal correction. It is reliable and easy to use.
AB - Our aim was to review the efficacy of the wound vacuum-assisted closure (VAC) system in the treatment of deep infection after extensive instrumentation and fusion for spinal deformity in children and adolescents. A total of 14 patients with early deep spinal infection were treated using this technique. Of these, 12 had neuromuscular or syndromic problems. Clinical and laboratory data were reviewed. The mean follow-up was 44 months (24 to 72). All wounds healed. Two patients required plastic surgery to speed up the process. In no patient was the hardware removed and there was no loss of correction or recurrent infection. We believe that the wound VAC system is a useful tool in the armamentarium of the spinal surgeon dealing with patients susceptible to wound infections, especially those with neuromuscular diseases. It allows for the retention of the instrumentation and the maintenance of spinal correction. It is reliable and easy to use.
UR - http://www.scopus.com/inward/record.url?scp=41149121143&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=41149121143&partnerID=8YFLogxK
U2 - 10.1302/0301-620X.90B3.19890
DO - 10.1302/0301-620X.90B3.19890
M3 - Review article
C2 - 18310764
SN - 0301-620X
VL - 90
SP - 377
EP - 381
JO - Journal of Bone and Joint Surgery - Series B
JF - Journal of Bone and Joint Surgery - Series B
IS - 3
ER -