@article{a506d7b08988415d8e40df523e376113,
title = "Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements",
author = "Clarkc, {I. C.} and V. Good and P. Williams and D. Schroeder and L. Anissian and A. Stark and H. Oonishi and J. Schuldics and G. Gustafson",
note = "Abstract With the increased clinical interest in metal-on-metal and ceramic-on-ceramic total-hip replacements (THRs), the objective of this hip simulator study was to identify the relative wear ranking of three bearing systems, namely CoCr-polyethylene (M-PE), CoCr-CoCr (M-M) and ceramic-on-ceramic (C-C). Volumetric wear rates were used as the method of comparison.",
year = "2000",
doi = "10.1243/0954411001535381",
language = "English",
volume = "214",
pages = "331--347",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
number = "4",
}