Real-time sonographically guided percutaneous dilatational tracheostomy using a long-axis approach compared to the landmark technique

Vi Am Dinh, Siavash Farshidpanah, Samantha Lu, Phillip Stokes, Ara Chrissian, Harsh Shah, Paresh Giri, David Hecht, H. Bryant Nguyen

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives-Sonographic evaluation of neck anatomy before performing percutaneous dilatational tracheostomy (PDT) has been shown to predict PDT success. In this study, we compared the real-time, long-axis, in-plane approach to the traditional bronchoscopically guided landmark technique. Methods-Data were analyzed from a prospectively maintained PDT database at a university tertiary care medical intensive care unit. A convenience sample of adult patients requiring PDT for prolonged mechanical ventilation dependence was enrolled. Critical care fellows, under direct supervision of an attending intensivist, performed all PDTs. Tracheostomy performance from the sonographically guided and landmark techniques was compared. Results-Twenty-three patients were enrolled: 11 in the sonography group and 12 in the landmark group. Initial midline introducer needle puncture was achieved in 72.7% in the sonography group compared to 8.3% in the landmark group (P< .001). The mean number of introducer needle punctures ± SD was significantly lower in the sonography group compared to the landmark group (1.4 ± 0.7 versus 2.6 ± 0.9; P < .001). The totaltracheostomy time was 11.4 ± 4.2 minutes in the sonography group versus 15.3 ± 6.8 minutes in the landmark group (P = .12). Sonography accurately predicted tracheal ring space insertion in 90.9% of patients. Procedural complications did not differ significantly between the groups. Conclusions-Percutaneous dilatational tracheostomy under real-time sonographic guidance using a long-axis approach may increase the rate of midline punctures and decrease the number of needle punctures when compared to the landmark technique. Sonographic guidance can also help guide accurate and efficient placement of a tracheostomy tube into the desired tracheal ring space. © 2014 by the American Institute of Ultrasound in Medicine.
Original languageEnglish
Pages (from-to)1407-1415
Number of pages9
JournalJournal of Ultrasound in Medicine
Volume33
Issue number8
DOIs
StatePublished - Aug 1 2014

ASJC Scopus Subject Areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Keywords

  • Long axis
  • Percutaneous dilatational tracheostomy
  • Point-of-care ultrasound
  • Simulation
  • Sonographic guidance
  • Training
  • Reproducibility of Results
  • Prospective Studies
  • Ultrasonography, Interventional/methods
  • Trachea/diagnostic imaging
  • Humans
  • Middle Aged
  • Male
  • Tracheostomy/methods
  • Computer Systems
  • Female

Cite this