Abstract
Purpose: We describe a useful technique for untying a knotted ureteral catheter. Materials and Methods: An Amplatz super stiff guide wire was advanced through the lumen of the stent and with uniform force the knot was untied. Results: The knot was untied and the stent was removed. A nephrostomy tube or other more invasive techniques for removal were avoided. Conclusions: An Amplatz super stiff guide wire passed retrograde via the ureteral stent lumen should be considered as a valid alternative to percutaneous removal of a knotted ureteral stent.
Original language | English |
---|---|
Pages (from-to) | 2065-2066 |
Number of pages | 2 |
Journal | The Journal of urology |
Volume | 159 |
Issue number | 6 |
DOIs | |
State | Published - Jun 1998 |
ASJC Scopus Subject Areas
- Urology
Keywords
- Adverse effects
- Stents
- Ureter