T1 - Evaluation of pulse cooximetry in patients undergoing abdominal or pelvic surgery
AU - Applegate, Richard L.
AU - Barr, Steven J.
AU - Collier, Carl E.
AU - Rook, James L.
AU - Mangus, Dustin B.
AU - Allard, Martin W.
N1 - Professor, †Resident in Anesthesiology, ‡Associate Professor, §Research Assistant, Department of Anesthesiology, Loma Linda University School of Medicine, Loma Linda, California. PATIENTS undergoing major abdominal or pelvic surgery can experience significant intraoperative blood loss. There is growing evidence that perioperative transfusion is associated with postoperative morbidity in at ...
PY - 2012/1
Y1 - 2012/1
N2 - BACKGROUND:: Intraoperative transfusion decisions generally are guided by blood loss estimation and periodic invasive hemoglobin measurement. Continuous hemoglobin measurement by pulse cooximetry (pulse hemoglobin; Rainbow® SET Pulse CO-Oximeter, Masimo Corporation, Irvine, CA) has good agreement with laboratory hemoglobin in healthy volunteers and could aid transfusion decision-making. Because intraoperative physiology may alter performance of this device, this study investigated pulse hemoglobin during surgery. METHODS:: Ninety-one adult patients undergoing abdominal or pelvic surgery in which large blood loss was likely were studied. Time-matched pulse hemoglobin measurements were recorded for each intraoperative arterial hemoglobin measurement obtained. Agreement between measurements was assessed by average difference (mean ± SD, g/dl), linear regression, and multiple measures Bland-Altman analysis. RESULTS:: The average difference between 360 time-matched measurements (bias) was 0.50 ± 1.44 g/dl, with wider limits of agreement (-2.3 to 3.3 g/dl) than reported in healthy volunteers. The average difference between 269 paired sequential pulse and arterial hemoglobin changes was 0.10 ± 1.11 g/dl, with half between -0.6 and 0.7 g/dl of each other. The bias was larger in patients with blood loss of more than 1,000 ml; hemoglobin less than 9.0 g/dl; any intraoperative transfusion; or intraoperative decrease in arterial hemoglobin at the time of sampling 2 g/dl (all P < 0.001). The range of bias was narrower at deeper anesthesia (P < 0.001). CONCLUSIONS:: Evaluation of the sensor and software version tested suggests that although pulse cooximetry may perform well in ambulatory subjects, in patients undergoing surgery in which large blood loss is likely, an invasive measurement should be used in transfusion decision-making.
AB - BACKGROUND:: Intraoperative transfusion decisions generally are guided by blood loss estimation and periodic invasive hemoglobin measurement. Continuous hemoglobin measurement by pulse cooximetry (pulse hemoglobin; Rainbow® SET Pulse CO-Oximeter, Masimo Corporation, Irvine, CA) has good agreement with laboratory hemoglobin in healthy volunteers and could aid transfusion decision-making. Because intraoperative physiology may alter performance of this device, this study investigated pulse hemoglobin during surgery. METHODS:: Ninety-one adult patients undergoing abdominal or pelvic surgery in which large blood loss was likely were studied. Time-matched pulse hemoglobin measurements were recorded for each intraoperative arterial hemoglobin measurement obtained. Agreement between measurements was assessed by average difference (mean ± SD, g/dl), linear regression, and multiple measures Bland-Altman analysis. RESULTS:: The average difference between 360 time-matched measurements (bias) was 0.50 ± 1.44 g/dl, with wider limits of agreement (-2.3 to 3.3 g/dl) than reported in healthy volunteers. The average difference between 269 paired sequential pulse and arterial hemoglobin changes was 0.10 ± 1.11 g/dl, with half between -0.6 and 0.7 g/dl of each other. The bias was larger in patients with blood loss of more than 1,000 ml; hemoglobin less than 9.0 g/dl; any intraoperative transfusion; or intraoperative decrease in arterial hemoglobin at the time of sampling 2 g/dl (all P < 0.001). The range of bias was narrower at deeper anesthesia (P < 0.001). CONCLUSIONS:: Evaluation of the sensor and software version tested suggests that although pulse cooximetry may perform well in ambulatory subjects, in patients undergoing surgery in which large blood loss is likely, an invasive measurement should be used in transfusion decision-making.
UR - http://www.scopus.com/inward/record.url?scp=84655175025&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84655175025&partnerID=8YFLogxK
U2 - 10.1097/ALN.0b013e31823d774f
DO - 10.1097/ALN.0b013e31823d774f
M3 - Article
C2 - 22133758
SN - 0003-3022
VL - 116
SP - 65
EP - 72
JO - Anesthesiology
JF - Anesthesiology
IS - 1
ER -