TY - JOUR
T1 - Comparison of the glidescope cobalt® and storz dci® video laryngoscopes in children younger than 2 years of age during manual in-line stabilization
T2 - A randomized trainee evaluation study
AU - Vadi, Marissa G.
AU - Roddy, Katie J.
AU - Ghazal, Elizabeth A.
AU - Um, Michael
AU - Neiheisel, Andrew J.
AU - Applegate, Richard L.
N1 - Publisher Copyright:
Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2017/7/1
Y1 - 2017/7/1
N2 - Objectives Video laryngoscopy facilitates tracheal intubation during manual in-line stabilization in adults, but it is not clear whether these findings translate to children. We compared trainee intubation times obtained using the GlideScope Cobalt® and Storz DCI® video laryngoscopes versus direct laryngoscopy in young children with immobilized cervical spines. Methods Ninety-three children younger than 2 years underwent laryngoscopy with manual in-line stabilization using direct laryngoscopy, GlideScope Cobalt® video laryngoscopy, or Storz DCI® video laryngoscopy. Laryngoscopists were anesthesiology trainees in postgraduate training year of 3 or more. Total time to successful intubation (TTSI), best glottic view, and maximum degrees of neck deviation were recorded. An intubation time difference longer than 10 seconds was defined as clinically significant. Results Data are reported as median; 95% confidence interval. The TTSI was similar among groups although Storz times were longer (median, 33.3 seconds; 95% confidence interval, 26.2-43.3 seconds) when compared to direct laryngoscopy (median, 23.3 seconds; 95% confidence interval, 20.7-26.5 seconds; P = 0.02). Obtaining a grade 1 Cormack-Lehane glottic view was less likely with direct laryngoscopy (P = 0.002). Maximum degrees of neck deviation were: Storz (median, 2.0; 95% confidence interval, 1.2-2.8), GlideScope (median, 2.0; 95% confidence interval, 1.4-2.6), and direct laryngoscopy (median, 1.9; 95% confidence interval, 1.2-2.1; P = 0.48). Conclusions Trainees were able to safely perform tracheal intubation in children younger than 2 years using any of the studied laryngoscopes, although Storz use resulted in a longer TTSI when compared to direct laryngoscopy. Video laryngoscopy may enhance best Cormack-Lehane glottic view during manual in-line cervical spine immobilization, but additional technical skills are needed to successfully complete tracheal intubation.
AB - Objectives Video laryngoscopy facilitates tracheal intubation during manual in-line stabilization in adults, but it is not clear whether these findings translate to children. We compared trainee intubation times obtained using the GlideScope Cobalt® and Storz DCI® video laryngoscopes versus direct laryngoscopy in young children with immobilized cervical spines. Methods Ninety-three children younger than 2 years underwent laryngoscopy with manual in-line stabilization using direct laryngoscopy, GlideScope Cobalt® video laryngoscopy, or Storz DCI® video laryngoscopy. Laryngoscopists were anesthesiology trainees in postgraduate training year of 3 or more. Total time to successful intubation (TTSI), best glottic view, and maximum degrees of neck deviation were recorded. An intubation time difference longer than 10 seconds was defined as clinically significant. Results Data are reported as median; 95% confidence interval. The TTSI was similar among groups although Storz times were longer (median, 33.3 seconds; 95% confidence interval, 26.2-43.3 seconds) when compared to direct laryngoscopy (median, 23.3 seconds; 95% confidence interval, 20.7-26.5 seconds; P = 0.02). Obtaining a grade 1 Cormack-Lehane glottic view was less likely with direct laryngoscopy (P = 0.002). Maximum degrees of neck deviation were: Storz (median, 2.0; 95% confidence interval, 1.2-2.8), GlideScope (median, 2.0; 95% confidence interval, 1.4-2.6), and direct laryngoscopy (median, 1.9; 95% confidence interval, 1.2-2.1; P = 0.48). Conclusions Trainees were able to safely perform tracheal intubation in children younger than 2 years using any of the studied laryngoscopes, although Storz use resulted in a longer TTSI when compared to direct laryngoscopy. Video laryngoscopy may enhance best Cormack-Lehane glottic view during manual in-line cervical spine immobilization, but additional technical skills are needed to successfully complete tracheal intubation.
KW - spine immobilization
KW - video laryngoscopy
KW - Intubation, Intratracheal/methods
KW - Prospective Studies
KW - Laryngoscopes
KW - Humans
KW - Infant
KW - Male
KW - Cobalt
KW - Equipment Design
KW - Laryngoscopy/instrumentation
KW - Video Recording
KW - Female
UR - http://www.scopus.com/inward/record.url?scp=84954554367&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84954554367&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/a680fe54-6cf7-3fb0-bf58-5fc85e284561/
U2 - 10.1097/PEC.0000000000000607
DO - 10.1097/PEC.0000000000000607
M3 - Article
C2 - 26785097
SN - 0749-5161
VL - 33
SP - 467
EP - 473
JO - Pediatric Emergency Care
JF - Pediatric Emergency Care
IS - 7
ER -