TY - JOUR
T1 - Analytical and clinical evaluation of the Bio-Rad HPLC kit for measurement of type I collagen cross links
AU - Srivastava, Apurva K.
AU - Libanati, Cesar
AU - Oberrauch, Walter
AU - Leenings, Joerg
AU - Greenwald, Maria
AU - Baylink, David J.
N1 - Analytical and clinical evaluation of the Bio-Rad HPLC kit for measurement of type I collagen cross links SRIVASTAVA APURVA K. , LIBANATI CESAR , OBERRAUCH WALTER , LEENINGS JOERG , GREENWALD MARIA , BAYLINK DAVID J. Journal of bone and mineral metabolism 21(3), 134-144, 2003-03-30
PY - 2003
Y1 - 2003
N2 - The measurement of hydroxylysylpyridinoline (PYD) and lysylpyridinoline (DPD), the degradation products of type I collagen, by manual HPLC assay posed practical difficulties. The present study was undertaken to evaluate the first commercially available HPLC kit, which provides a convenient substitute for cumbersome classical HPLC methods. The HPLC procedure is based on an improved sample clean-up chromatography, convenient ready-to-use HPLC reagents, and quicker isocratic elution of PYR and DPD on reverse-phase analytical column. The analytical parameters assessed include sensitivity, within- and between-assay variation, method comparison, recoveries, and interference. Clinical evaluation included discriminatory power of PYD and DPD and response to treatment of osteoporosis patients with Alendronate. DPD and PYD concentrations showed linear (r2 > 0.99) response between 10-400 pmol/ml and 75-4000 pmol/ ml, respectively. The average within-assay imprecision, over a range of clinically relevant cross-links concentrations, was CV < 7% (n = 30). The total imprecision (n = 35 days), by ANOVA, for PYD and DPD was CV < 7.5% and CV < 10%, respectively. Average spike recovery was 95.4% ± 6.5%. Comparison with the historical HPLC method exhibited a close correlation (r values between 0.87 and 0.91, P < 0.0001). Creatinine-corrected DPD in postmenopausal (Z score = 2.4, P < 0.05, n = 17) and osteoporotic (Z score = 3.0, P < 0.01, n = 29) women were 44% and 64% higher, respectively, compared to premenopausal samples (n = 15). Similarly, PYD concentration was 26% and 54% higher in postmenopausal and postmenopausal osteoporotic women, respectively. There was a 47% (P < 0.001) decrease in DPD concentration (n = 16), and a 30% decrease in PYD concentration after 90 days of treatment of osteoporotic patients with Alendronate. DPD concentration correlated with N-telopeptide with an r value of 0.69 (n = 67, P < 0.0001). The reported kit method is substantially simpler and precise than the manual method. DPD concentrations determined by the current method reaffirm the clinical value in identifying increased bone resorption in pathological conditions and monitoring response to anti-resorptive therapy.
AB - The measurement of hydroxylysylpyridinoline (PYD) and lysylpyridinoline (DPD), the degradation products of type I collagen, by manual HPLC assay posed practical difficulties. The present study was undertaken to evaluate the first commercially available HPLC kit, which provides a convenient substitute for cumbersome classical HPLC methods. The HPLC procedure is based on an improved sample clean-up chromatography, convenient ready-to-use HPLC reagents, and quicker isocratic elution of PYR and DPD on reverse-phase analytical column. The analytical parameters assessed include sensitivity, within- and between-assay variation, method comparison, recoveries, and interference. Clinical evaluation included discriminatory power of PYD and DPD and response to treatment of osteoporosis patients with Alendronate. DPD and PYD concentrations showed linear (r2 > 0.99) response between 10-400 pmol/ml and 75-4000 pmol/ ml, respectively. The average within-assay imprecision, over a range of clinically relevant cross-links concentrations, was CV < 7% (n = 30). The total imprecision (n = 35 days), by ANOVA, for PYD and DPD was CV < 7.5% and CV < 10%, respectively. Average spike recovery was 95.4% ± 6.5%. Comparison with the historical HPLC method exhibited a close correlation (r values between 0.87 and 0.91, P < 0.0001). Creatinine-corrected DPD in postmenopausal (Z score = 2.4, P < 0.05, n = 17) and osteoporotic (Z score = 3.0, P < 0.01, n = 29) women were 44% and 64% higher, respectively, compared to premenopausal samples (n = 15). Similarly, PYD concentration was 26% and 54% higher in postmenopausal and postmenopausal osteoporotic women, respectively. There was a 47% (P < 0.001) decrease in DPD concentration (n = 16), and a 30% decrease in PYD concentration after 90 days of treatment of osteoporotic patients with Alendronate. DPD concentration correlated with N-telopeptide with an r value of 0.69 (n = 67, P < 0.0001). The reported kit method is substantially simpler and precise than the manual method. DPD concentrations determined by the current method reaffirm the clinical value in identifying increased bone resorption in pathological conditions and monitoring response to anti-resorptive therapy.
KW - Alendronate
KW - Collagen crosslinks
KW - Deoxypyridinoline
KW - HPLC
KW - Postmenopausal osteoporosis
KW - Pyridinoline
UR - https://www.scopus.com/pages/publications/0642336856
UR - https://www.scopus.com/pages/publications/0642336856#tab=citedBy
U2 - 10.1007/s007740300022
DO - 10.1007/s007740300022
M3 - Article
C2 - 12720047
SN - 0914-8779
VL - 21
SP - 134
EP - 144
JO - Journal of Bone and Mineral Metabolism
JF - Journal of Bone and Mineral Metabolism
IS - 3
ER -