TY - JOUR
T1 - An evaluation of patient self-testing competency of prothrombin time for managing anticoagulation
T2 - pre-randomization results of VA Cooperative Study #481--The Home INR Study (THINRS).
AU - Dolor, Rowena J.
AU - Ruybalid, R. Lynne
AU - Uyeda, Lauren
AU - Edson, Robert G.
AU - Phibbs, Ciaran
AU - Vertrees, Julia E.
AU - Shih, Mei Chiung
AU - Jacobson, Alan K.
AU - Matchar, David B.
AU - THINRS Site Investigators, Site Investigators
N1 - Funding Information:
The study was sponsored by the Department of Veterans Affairs, Veterans Health Administration, Office of Research and Development, Clinical Sciences Research and Development Service, Cooperative Studies Program, 810 Vermont Avenue, NW, Washington, DC 20420.
PY - 2010/10
Y1 - 2010/10
N2 - Prior studies suggest patient self-testing (PST) of prothrombin time (PT) can improve the quality of anticoagulation (AC) and reduce complications (e.g., bleeding and thromboembolic events). "The Home INR Study" (THINRS) compared AC management with frequent PST using a home monitoring device to high-quality AC management (HQACM) with clinic-based monitoring on major health outcomes. A key clinical and policy question is whether and which patients can successfully use such devices. We report the results of Part 1 of THINRS in which patients and caregivers were evaluated for their ability to perform PST. Study-eligible patients (n = 3643) were trained to use the home monitoring device and evaluated after 2-4 weeks for PST competency. Information about demographics, medical history, warfarin use, medications, plus measures of numeracy, literacy, cognition, dexterity, and satisfaction with AC were collected. Approximately 80% (2931 of 3643) of patients trained on PST demonstrated competency; of these, 8% (238) required caregiver assistance. Testers who were not competent to perform PST had higher numbers of practice attempts, higher cuvette wastage, and were less able to perform a fingerstick or obtain blood for the cuvette in a timely fashion. Factors associated with failure to pass PST training included increased age, previous stroke history, poor cognition, and poor manual dexterity. A majority of patients were able to perform PST. Successful home monitoring of PT with a PST device required adequate levels of cognition and manual dexterity. Training a caregiver modestly increased the proportion of patients who can perform PST.
AB - Prior studies suggest patient self-testing (PST) of prothrombin time (PT) can improve the quality of anticoagulation (AC) and reduce complications (e.g., bleeding and thromboembolic events). "The Home INR Study" (THINRS) compared AC management with frequent PST using a home monitoring device to high-quality AC management (HQACM) with clinic-based monitoring on major health outcomes. A key clinical and policy question is whether and which patients can successfully use such devices. We report the results of Part 1 of THINRS in which patients and caregivers were evaluated for their ability to perform PST. Study-eligible patients (n = 3643) were trained to use the home monitoring device and evaluated after 2-4 weeks for PST competency. Information about demographics, medical history, warfarin use, medications, plus measures of numeracy, literacy, cognition, dexterity, and satisfaction with AC were collected. Approximately 80% (2931 of 3643) of patients trained on PST demonstrated competency; of these, 8% (238) required caregiver assistance. Testers who were not competent to perform PST had higher numbers of practice attempts, higher cuvette wastage, and were less able to perform a fingerstick or obtain blood for the cuvette in a timely fashion. Factors associated with failure to pass PST training included increased age, previous stroke history, poor cognition, and poor manual dexterity. A majority of patients were able to perform PST. Successful home monitoring of PT with a PST device required adequate levels of cognition and manual dexterity. Training a caregiver modestly increased the proportion of patients who can perform PST.
UR - http://www.scopus.com/inward/record.url?scp=85027957736&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85027957736&partnerID=8YFLogxK
U2 - 10.1007/s11239-010-0499-8
DO - 10.1007/s11239-010-0499-8
M3 - Article
C2 - 20628787
SN - 0929-5305
VL - 30
SP - 263
EP - 275
JO - Journal of Thrombosis and Thrombolysis
JF - Journal of Thrombosis and Thrombolysis
IS - 3
ER -