N1 - Patients with complete heart block on a spontaneous, or iatrogenic basis who also have recurrent supraventricular tachycardias, particularly atrial fibrillation and flutter, are often difficult to manage. Various techniques include: independently programmable maximum tracking and maximum sensor rates, limiting the maximum atrial tracking rate to the sensor response of the pacemaker, or automatically switching from DDDR to VVIR based upon the sensed atrial rate.
PY - 1994/11
Y1 - 1994/11
N2 - Patients with complete heart block on a spontaneous, or iatrogenic basis who also have recurrent supraventricular tachycardias, particularly atrial fibrillation and flutter, are often difficult to manage. Various techniques include: independently programmable maximum tracking and maximum sensor rates, limiting the maximum atrial tracking rate to the sensor response of the pacemaker, or automatically switching from DDDR to VVIR based upon the sensed atrial rate. This article will describe a mode switch algorithm that allows for an independently programmable atrial tachycardia detection rate (ATDR). This allows mode switching to occur only in response to the patient's pathological tachyarrhythmia, and not during normal upper rate response. The ATDR is based upon a filtered atrial rate, which will prevent an isolated premature beat from initiating the algorithm. In addition, the unit can be programmed to switch to either DDI, DDIR, VVI, or VVIR. Extensive event counters in the pulse generator allows the system to record and store the number of algorithm activations, the average atrial rate which triggered each mode switch, and the duration of the mode switch. These reports are accessible at each follow‐up visit.
AB - Patients with complete heart block on a spontaneous, or iatrogenic basis who also have recurrent supraventricular tachycardias, particularly atrial fibrillation and flutter, are often difficult to manage. Various techniques include: independently programmable maximum tracking and maximum sensor rates, limiting the maximum atrial tracking rate to the sensor response of the pacemaker, or automatically switching from DDDR to VVIR based upon the sensed atrial rate. This article will describe a mode switch algorithm that allows for an independently programmable atrial tachycardia detection rate (ATDR). This allows mode switching to occur only in response to the patient's pathological tachyarrhythmia, and not during normal upper rate response. The ATDR is based upon a filtered atrial rate, which will prevent an isolated premature beat from initiating the algorithm. In addition, the unit can be programmed to switch to either DDI, DDIR, VVI, or VVIR. Extensive event counters in the pulse generator allows the system to record and store the number of algorithm activations, the average atrial rate which triggered each mode switch, and the duration of the mode switch. These reports are accessible at each follow‐up visit.
KW - DDD pacing
KW - DDDR pacing
KW - automode switch algorithm
KW - supraventricular tachycardias
KW - upper rate behavior
UR - http://www.scopus.com/inward/record.url?scp=0028109709&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028109709&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.1994.tb03770.x
DO - 10.1111/j.1540-8159.1994.tb03770.x
M3 - Article
C2 - 7845788
SN - 0147-8389
VL - 17
SP - 1895
EP - 1899
JO - Pacing and Clinical Electrophysiology
JF - Pacing and Clinical Electrophysiology
IS - 11
ER -